ELECTRICAL REQUIREMENTS
- E-XP-2 (High Pressure) Max: 230 V, 3 phase, 60 amp
- E XP-2 (High Pressure) Max: 230 V, 1 phase, 100 amp
- E-10 (Low Pressure) Max: 120 V, 20 amp
COMPRESSOR (E-10 & E-XP-2 only)
- Minimum 7.5 HP (220 V, 1 phase, 35 amp) two stage with 80-gallon tank capable of 25 CFM @ 100 psi to be used exclusively for equipment only. Automatic drain is highly recommended.
- Minimum 10 HP with 120-gallon tank may be necessary if others in the shop will be using air tools simultaneously.
COMPRESSOR (Cartrige Gun & Hopper Gun only)
- Minimum 3 HP (230 V, 1 phase) 2 cylinder with 60-gallon tank capable of 11.3 CFM @ 90 psi to be used exclusively for equipment only. Automatic drain is highly recommended.
- Minimum 5 HP with 80-gallon tank may be necessary if others in the shop will be using air tools simultaneously.
REFRIGERANT DRYER
- The spray air needs to be less than 5% relative humidity as it leaves the gun.
- A 3-in-1 refrigerant dryer for you compressor is mandatory.
EQUIPMENT & MATERIAL ROOM (E-10 & E-XP-2 only)
- Minimum 10ft wide X 10ft long X 8ft high fully insulated walls and ceiling.
- Recommended to be located next to spray room with common wall to spray area.
- Heated vents located on 3 corners at bottom of wall 2 ft from the floor.
- Air intake on 1 corner at bottom of the wall 2 ft from the floor.
- Heater must be capable of maintaining the room at 80F – 90F 24 hrs a day, 7 days a week. No open flame heaters. Radiant or infrared heater with adjustable thermostat works best.
- A small A/C window unit may be necessary in parts of the country where shop temperatures reach 100F.
APPLICATION AREA - for truck bedliners only
- One truck: 16ft wide x 16ft deep x 11ft high (minimum)
- Two trucks: 24ft wide x 18ft deep x 11ft high (minimum)
- Flourescent lighting
- Tar paper on floor with duct tape
- Polyethylene curtains capable of completely enclosing spray area (NFPA 701 compliant)
- Ventilation fans must exhaust air 2-3 times per minute. Forced makeup air will be required. Heated air will be needed in colder climates. Note: To determine the CFM of exhaust fan, take total volume of the room and double that number. 3,000 cu ft room will require 6,000 cu ft fan.